Intercall 700 system
The INTERCALL 700 is the
latest innovation in the Intercall range of advanced call system.
The system boasts all the features of the Intercall 600 system together
with hands free two way speech facilities between all audio units.
All room call points have an integral infra red receiver, which
allows a call to be generated away from the call point without the
need for trailing wires. Using the TIR4 Infra Red Trigger it is
possible to identify the calling resident together with their location,
which can be used to rout the call to specific members of staff.
The system is fully addressable and only requires connection to
a common 12v network cable. The system is configured using a PC
compatible Computer or similar and may be programmed on or off site
as required.
|
|
|
|
L752 AUDIO CALL POINT
An L752 Audio Call Point is required for every individual audio
call location on the system. It features 7 levels of call, hands
free two way intercom, integral infra red receiver, audio page facility,
re-assurance LED & 'call waiting' sounder. The industry standard
jack socket will accept a host of triggering devices. The unit may
be flush or surface mounted using the Intercall BB1 Backbox.
|
|
|
|
L722 NON AUDIO CALL POINT
The L722 Non Audio Call Point contains identical features to the
audio call point described above but without the intercom facility.
Options which must be specified when ordering include: emergency
call only & non-latching operation for telephone ring detectors
etc.
|
|
|
|
L758 AUDIO DISPLAY UNIT
Audio display units are generally located throughout the establishment
and provide a description of the call type, location and identity
of caller together with sounding the integral alarm. It features
2 line back-lit display, multi function audible alarm, two way intercom
facility and audio page facility to all other displays and to all
members of staff present within a residents bedroom.
|
|
|
|
L762 CALL/DISPLAY UNIT
The L762 Call Display Unit combines the features of the speech call
point with a built in display. When in staff present mode the unit
will display all calls on the system in full alphanumeric text,
enabling staff to speak to other callers elsewhere on the system
without having to leave the room they are attending.
|
|
|
|
L722DK DOOR MONITORING POINT
The L722DK Door Monitoring Point can be used to protect fire doors,
exit doors and other sensitive areas. The unit has an isolated key-switch
in place of the jack socket, which can be used by authorized personnel
to isolate the unit and prevent it from activating the alarm. The
L722DK activates an "Emergency" call as standard and can
be reset with a single press of the reset button.
|
|
|
|
L714 REMOTE SOUNDER WITH RELAY
Remote sounders are used in areas where an audible alarm is required
to attract attention but no indication of call location is required.
The sounder is similar in operation to a display unit with a multi
level alarm, but has limited zoning facilities. Any assistance or
emergency call on the system will over-ride the standard call tone.
The unit is fitted with a relay that provides normally open and
normally closed 'dry' contacts, which can be used to trigger auxiliary
devices.
|
|
|
|
L746 OVERDOOR LIGHT
Overdoor lights are an optional item normally positioned above the
door in a corridor to indicate the status of the call point(s) within
the room. The L746 can also be used to monitor several call point
addresses for end of corridor indication, or as a "follow me"
light. Each unit is fitted with twin ultra-bright LED's which mimic
the reassurance indicator on the call points. The L746S unit operates
in the same way as the standard overdoor light but has the addition
of an integral sounder.
|
|
|
|
L717 & L737 POWER SUPPLY
The L717 Power Supply provides the main power to the system. It
requires a mains supply connection and it houses the backup battery,
required to safeguard the system in the event of a mains failure.
The power supply stores all the text programming information and
can also be used to configure the system when a laptop is connected.
The L737 Booster Power Supply unit is designed to increase the permitted
number of units and quantity of cable allowed on any one system.
It works by re-producing the signals made by the power supply, and
several booster units may be connected as required.
|
|
|
|
PRINTERS AND ALPHANUMERIC PAGERS
Printers and alphanumeric pagers can be connected to the system
with the L747 Universal Interface. The printer provides a permanent
printed record of all system activity together with date and time.
Pagers can be configured to display calls made on the system as
they would appear on the display unit. This allows staff to carry
on with their work without having to worry about missing calls.
Pagers can also be specially configured to only receive certain
calls, or calls at certain times of the day.
|
|
|
|
CMS LITE CALL MANAGEMENT SOFTWARE
The CMS Lite Call Management Software allows you to record and store
all Intercall system activity on your personal computer. Giving
you immediate access to information, it is easy to access the call
history of a resident, keeping you in charge of your home. Staff
pagers can also be controlled from your computer, allowing free
text messages to be sent to individual pagers.
|
|
|
TIR4
INFRA RED TRIGGER
The TIR4 Infra Red Trigger allows calls to be made from any location
covered by the system. It operates by triggering the local IR call
point when the button is pressed, allowing the exact location of the
resident to be displayed. The TIR4 triggers requires the use of L722
Call Points which have built in Infra Red receivers, to trigger the
system. |
|
|