WS10U
X10 UK Mains Socket
At last we finally have a UK
X10 mains socket! No longer is there a need for plug in modules
when you want a permanent X10 solution. The WS10 replaces a double
gang UK mains socket, and gives you a single gang X10 controlled
socket (the other gang is used to house the X10 electronics).
To install the unit:
1. Turn off the mains electricity!
2. Remove your existing socket, from it's metel back box.
3. Remove the 1 gang socket from the main body of WS10 - this
will reveal 3 unused screw-down connections.
4. Fit the Positive (L), Neutral (N), and Ground/Earth lives into
the WS10, taking care that no strands of wires are loose or touching
the outputs.
5. Re-fit the single gang socket onto the front of the WS10 main
body.
6. Fit the WS10 onto the double metel back box.
|